Methodology
How Sphere Design Hub calculations are verified
Every calculator in Sphere Design Hub follows EN 1992-1-1 (Eurocode 2) and writes out each step of the design with its clause reference, so the engineer can check the working, not only the answer.
01Testing
How the engines are checked
- 01Changes to a calculator are tested by sending real design requests to the running engine and comparing the results with independent hand calculations.
- 02Where a result can be worked out in closed form (for example wL²/8 for a simply supported span, or the three-moment equation for continuous spans) the engine's numbers are compared with it directly.
- 03Frame and continuous analyses are cross-checked with an independent solver.
- 04Results are also compared with published worked examples. Where the software deliberately differs from an example, the difference is recorded rather than hidden.
02Reports
What the reports tell you
- 01The slab, beam, column and staircase reports list the nationally determined parameters the engine uses at the start of the report.
- 02Every check shows its demand, its resistance, the utilisation and the clause it comes from.
- 03Simplifications made by the engine are stated in the report and on the calculator pages, under limits and assumptions.
03Known simplifications
Where each calculator simplifies
Each calculator page lists its own limits. In summary:
- Beam: simply supported
- L01The crushing limit of the concrete struts (V_Rd,max) and the minimum link ratio are not checked. Check both by hand for heavily loaded or short beams.
- L02The detailing designs the span steel only: hogging steel at fixed ends is not detailed.
- Beam: continuous
- L01No pattern loading: every span carries the full design load at once. Check alternate-span loading by hand where live load is large compared with dead load.
- L02The quasi-permanent factor for cracking is taken as 0.6.
- Column
- L01Fire resistance is not checked.
- Slab: one-way and two-way
- L01Wind uplift (suction) is not checked: wind is a downward pressure only.
- L02Cover is not checked against the exposure class on the one-way slab (the two-way slab checks it only when no cover is entered).
- L03No fire or crack-width check on these two; the continuous slab has both.
- Continuous one-way slab
- L01Spans over 4.5 m are designed, with a note in the report.
- L02Crack control uses the ULS lever arm, which gives a steel stress about 3% lower than a cracked elastic section.
- L03Bar curtailment uses simplified rules (top bars 0.3 x the longer adjacent span each side of a support), stated in the report.
- Foundation: pad footing
- L01Bearing is a warning only: a footing that exceeds the allowable pressure still shows PASS overall. Read the Bearing tab.
- L02Edge and corner columns: the reduced punching perimeters are not modelled, so punching is reported as not applicable there. Check it by hand.
- L03The design approach (EN 1997-1) is not applied; bearing uses the allowable pressure you enter.
- L04Links are not scheduled for circular columns.
- Foundation: combined footing
- L01Two rectangular columns only.
- L02The engine does not add steel to pass shear; a shear failure needs a deeper footing.
- L03Bearing is a warning only, as for the pad footing.
- Staircase
- L01The pinned frame usually shows a small uplift at the landing support. It is reported as a warning, not a failure.
- L02The self-weight of the waist is taken on its thickness, without a slope factor.
04Responsibility
Who is responsible for the design
Sphere Design Hub is a design aid. Every result must be checked by a qualified structural engineer, who remains responsible for the design.